At 23:16 5/12/2000, Mark Drillock wrote: >of the gas line could result in a fire. If the tank regulator was >involved, the result might be spectacular. This seems unlikely but it is Mark, the POL spud on the regulator has a so-called "excess-flow" device (if not it's highly illegal) that shuts off if the flow is too high. That's one reason why using a BBQ-type regulator is so bad, because it's unlikely that the POL fitting will be correct. So anything downstream of that fitting that causes uncontrolled venting will be quickly shut off. If the valve gets knocked off the tank, that's a different story entirely, but just having the valve open has been covered by the approval authorities. david David Beierl - Providence, RI http://pws.prserv.net/synergy/Vanagon/ '84 Westy "Dutiful Passage" '85 GL "Poor Relation" |
Please note - During the past 17 years of operation, several gigabytes of
Vanagon mail messages have been archived. Searching the entire collection
will take up to five minutes to complete. Please be patient!
Return to the archives @ gerry.vanagon.com
The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.