I've been sorting out fridge problems with help from the list for the last 2 weeks. What has helped me particularly has been the advice to seal everything with silicone that might cause air leaks and to check the actual pressure output of my regulator. If you opened the combustion box at the back for cleaning/blowing out there might be an air leak. If you're going to be at high altitudes in SA you might want to verify your regulator output so you can decrease the pressure output to keep the flame going. Since the problem occurred when you cleaned it I suspect the former, but while you're at it you might want to replace the regulator if it's the original square type. They can fail. FWIW I checked around here for new regulators and could only find a sealed, non adjustable type so far. Good luck,
Ken Hunter 82 Westy 1.9D 84 Jetta 1.5D 89 Mitsubishi van |
Please note - During the past 17 years of operation, several gigabytes of
Vanagon mail messages have been archived. Searching the entire collection
will take up to five minutes to complete. Please be patient!
Return to the archives @ gerry.vanagon.com
The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.