I don't know but something is still not right. You should be seeing around 200+ high side numbers if your temps are in the mid to upper 80s (low 90s) and around 40 or less psi on the low side. It really sounds like your expansion valve is wacky to me. The new ones are setup for R-134a not R-12. I wouldn't think this would make too much of a difference but I haven't been recharging stuff with R-12 so I don't know for sure. At the most I have put 4 1/2 pounds in a system before (usually 3 or just a bit more does the trick). Thanks, Ken Wilford http://www.vanagain.com John 3:16 New Phone (856)-327-4936 Shop: (856)-765-1583 Fax: (856)-327-2242 |
Please note - During the past 17 years of operation, several gigabytes of
Vanagon mail messages have been archived. Searching the entire collection
will take up to five minutes to complete. Please be patient!
Return to the archives @ gerry.vanagon.com
The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.