I was debugging my cruise control last night using the Bentley manual. When it came time to check the resistance of the inductive speed sensor (located on the back of the speedometer) the manual called for 90 to 110 ohms. My DMM showed 1.1K. This is 10 times larger than the manual calls for. Since 10 is nice round number I was wondering if the manual might have a typo and the actual reading should be 900 - 1100 ohms. Anyone out there measure this before and what was your reading? Noel - 88 GL |
Please note - During the past 17 years of operation, several gigabytes of
Vanagon mail messages have been archived. Searching the entire collection
will take up to five minutes to complete. Please be patient!
Return to the archives @ gerry.vanagon.com
The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.