Ed DeBolt wrote: > > Hi Vgoners > > well the mercury hit 108 here in Reno yesterday. Thats a record with no > higher temp recorded since 1886. > > My 87 has blown cool air a few years ago when I bought it but has never been > recharged and it is not converted. I took the belt off over a year ago. > > So this is my plan. > > Put a new belt on > get the system evacuated of R-12 > replace the dryer > use the 134 conversion kit from BD > > Just wondering if anyone has any tips for me. Is changing the dryer > difficult? Should I change any other O rings etc at the same time? When the > system is evacuated is it safe i.e free of toxic freon for me to work on? > > Is it possible or helpful to have the system pressure checked? would such a > test indicate compressor issues? > > I'm hoping my compressor is okay. I read in the archives that not having a > belt on it is bad because the seals are lubricated by the belt/pump action. > > Thanks for any tips. > > Ed > Reno, NV > 87 GL Hi I converted my 91 to 134a about a year ago. I had the belt off for about a year and it didn't seem to hurt it. If yours leaked enough to stop working a year ago, there is probably not enough r-12 left to worry about. You want new O-rings at the dryer and the compressor. It's best to dismount the compressor anyway to drain out as much of the mineral oil as possible. I assume that you're putting in some ester oil. Try not to let too much humid air get into the system when it is open. Use a real gauge set. Pull a good vacuum and then close the valves and watch the gauge for an hour or so to see if there is any significant leak that must be fixed. Then let the vacuum pump work for at least an hour to remove air and moisture. When charging, it helps to set the cans in warm water. When the high side pressure gets to a reasonable level ( a little over 200 psi if I recall) the high pressure switch will start to cycle the radiator fan to high speed as needed. This seems to be a reasonable charge level. The coldest air temp I have measured at the exit from the evaporator is about 48 F with the air in the cabin already cool. Generally the air coming out is about 30 F less than what goes in, with the temp control all the way up and the fan at 2. Mine still leaks a little; this summer I had to add about a can and a half to get it back to the performance I had last summer. I'm not sure, but this may be because those long hoses are not the "barrier type" recommended for R-134a. I have a Saab 900 that needs converting also. I'm about to try one of the hydrocarbon refrigerants this time. good luck, Larry A. |
Please note - During the past 17 years of operation, several gigabytes of
Vanagon mail messages have been archived. Searching the entire collection
will take up to five minutes to complete. Please be patient!
Return to the archives @ gerry.vanagon.com
The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.
Any profits from list compilations go exclusively towards the management and operation of the Vanagon mailing list and vanagon mailing list web site.