You can take a regular old 12 volt car or truck generator and crank out 120v all day long. Farm supply stores sell kits and also I think you can get the kits from Harbor Supply or Omaha Supply. These are common tools around ranches and farms if you're old enough to remember them. Getting regulated power is achieved through a solid state regulator that you tune for 50 or 60 Mhz power.

Stan Wilder

On Tue, 1 Oct 2002 20:03:09 -0600 westydriver <westydriver@TACTICAL-BUS.INFO> writes: > did a lot of info digging on gen sets a while back and got a pair > of > the little ones you see on ebay. nice little 1kw max 750 watt > normal > generators. most small generators are two stroke. this means > they are not candidates for lp or straight gas feeds. the larger > 4 > strokers are just that. large and heavy. this makes them not > very > portable. add to these the weight of an lp system and that is way > to > heavy. to take a straight feed from your vehicle gas tank is > something i wont recommend. way to many hazards. > > if you plan to mount internally like on some rv, the gen set must > be > isolated from the pax areas by a fire shield and fuel systems must > have cutoffs. exhaust must vent according to codes as well. > remote > start gen sets like some of the onan sets for rv are heavy, and > expensive and installations in a westy would be impossible if you > wanted to have any room left for you. > honda makes some small and extremely quiet and extremely expensive > gen > sets. not good for conversions either. > some notes on gen set safety. they vibrate like crazy, so check > fuel > hoses, fittings, carb fittings, after during and before each use. > have > an extinguisher handy whenever using a gen set. > i just carry an empty 1 gal gas can, a couple of measured bottle of > 2 > stroke oil, each good for 1 gallon of mix, and a siphon hose. > jimt > On Tuesday, Oct 1, 2002, at 19:35 America/Denver, 80 Westy Pokey > wrote: > > > I was thinking about a gas or LP geberator and I was > > wondering if anyone on the list has ever installed one? > > Where did you put it? What kind did you get? > > I would like to have a remote starter, wire it up to the > > vehicle's 110 electrical system, and have it feed from the > > vehicle's fuel or LP tank. > > Anyone been down this road? > > Thanks, > > Chris > >

________________________________________________________________ GET INTERNET ACCESS FROM JUNO! Juno offers FREE or PREMIUM Internet access for less! Join Juno today! For your FREE software, visit: http://dl.www.juno.com/get/web/.


Back to: Top of message | Previous page | Main VANAGON page

Please note - During the past 17 years of operation, several gigabytes of Vanagon mail messages have been archived. Searching the entire collection will take up to five minutes to complete. Please be patient!


Return to the archives @ gerry.vanagon.com


The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.

Any profits from list compilations go exclusively towards the management and operation of the Vanagon mailing list and vanagon mailing list web site.