Noel, I installed a secondard solenoid to compensate for my low voltage at the starter solenoid. It did work for about 1.5 years. Then I started having the same symptoms again. The van wouldn't start when it was hot and the electrical was heat soaked. So I went and replaced the wire from the ignition to the original starter solenoid. It worked like a charm. I have no starting hesitation and I removed the secondary solenoid. I recommend using about a 10 AWG wire for the wire to the starter. It's big but you won't ever have a problem with it as long as your contacts stay clean. Good Luck, Blake Heinlein '84 Automatic Westfalia (2.1L) |
Please note - During the past 17 years of operation, several gigabytes of
Vanagon mail messages have been archived. Searching the entire collection
will take up to five minutes to complete. Please be patient!
Return to the archives @ gerry.vanagon.com
The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.