isn't it the CONDENSOR (not the evaporator) where the refrigerant gas is pressurized and condensed into a liquid, and the EVAPORATOR (not the condenser) where this liquid is evaporated back into a gas??? The evaporation is what produces the cooling, much the same way that liquid sweat evaporating from the skin cools a human body. That's why the evaporator is inside the van...to blow cool air to the front, and the condenser is outside the van...to cool the warm refrigerant with ambient or fan forced air. Hold your favorite aerosol can upside down and push the button. You are now evaporating into the air, a liquid which was condensed into the canister and under pressure. The canister is your condenser (high pressure), the button your expansion valve and the temperature drop you feel of the resulting spray is the cool you feel from your evaporator (low pressure). The only difference in this case is that it's not a closed loop. Reverse the whole process and you have a heat pump.

-----Original Message----- From: Eric Zeno [mailto:vw4x4@FYI.NET] Sent: Thursday, August 07, 2003 11:32 AM To: vanagon@GERRY.VANAGON.COM Subject: Re: repost - basic a/c hose connection question.

Let think of it like this: You can not compress a liquid! High pressure gas out of compressor to evaporator that turn the freon into liquid Liquid goes to condensor turns to low pressure gas. Low pressure gas goes to compressor and the hold thing starts all over again.

Eric

Larry Alofs wrote:

> Eric Zeno wrote: > >> Output of the compressor goes to the evaporator. >> Input, or SUC goes to the condensor. >> Eric >> > I think that's backwards. > Output from compressor goes to condenser (in front). > From the evaporator (cold part) the refrigerant returns to the > compressor. (Haynes 3-11) > Larry A. > > > >> Owen wrote: >> >>> I posted this question yesterday. I apologize for the repost of this >>> but I am squeezed for time trying to get on the road for the weekend. >>> >>> Which hose connects to the SUC connection on the compressor? The one >>> going up to the evaporator or the one coming from the condenser up >>> front? >>> >>> My logic is that the long hose coming from the front of the van would >>> connect here. >>> >>> Since it wasn't hooked up when I bought it I am not sure. Clearly I >>> don't have the basic refrigeration principles down pat. >>> >>> Owen Brand >>> >>> >>> >>> >> > >


Back to: Top of message | Previous page | Main VANAGON page

Please note - During the past 17 years of operation, several gigabytes of Vanagon mail messages have been archived. Searching the entire collection will take up to five minutes to complete. Please be patient!


Return to the archives @ gerry.vanagon.com


The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.

Any profits from list compilations go exclusively towards the management and operation of the Vanagon mailing list and vanagon mailing list web site.