At 01:33 PM 10/3/2003, sam.cooks wrote: >I have to take my son to a doctor's appointment in 45 minutes. Can I >use the bottom bolt holding the coil bracket in place as an alternative >ground point. Seems to be an easy yes answer, as they all connect to >that same wall, but don't want to screw up the electronics by being wrong. Sure -- just clean it up nice and shiny to get a good connection to the actual body. Suggest going behind the bracket for that purpose, rather than on top. d ps -- grounds are not necessarily as simple as they look, but you should be ok here.
-- David Beierl - Providence RI USA -- http://pws.prserv.net/synergy/Vanagon/ '84 Westy "Dutiful Passage" '85 GL "Poor Relation" |
Please note - During the past 17 years of operation, several gigabytes of
Vanagon mail messages have been archived. Searching the entire collection
will take up to five minutes to complete. Please be patient!
Return to the archives @ gerry.vanagon.com
The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.