You started with Freeze 12. By most of the regulations I've seen for these propane derivative refrigerants, to be legal, they system should have first been converted to an R134 system (and that means the lubricants and connectors) first before Freeze 12 can be used in the system.

Then you switched to R12. However, unless the system was cleaned out and new R12 lubricants put into the system, you could have been mixing incompatible refridgerants/lubricants.

Switch everything over to R134 (including the connectors for hi and low sides. Make sure the proper lubricants are in the system that are compatible with R134. And sufficient amount of those lubricants (the length of refridgerant lines in a Vanagon means that you'll be using more lubricant in the AC system than is typical of other vehicles.

Once all the above is done, you should be able to use R134 or, after an evacuation of the system, Freeze 12, or Duracool without problems.


Back to: Top of message | Previous page | Main VANAGON page

Please note - During the past 17 years of operation, several gigabytes of Vanagon mail messages have been archived. Searching the entire collection will take up to five minutes to complete. Please be patient!


Return to the archives @ gerry.vanagon.com


The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.

Any profits from list compilations go exclusively towards the management and operation of the Vanagon mailing list and vanagon mailing list web site.