Vanagon EuroVan
Previous messageNext messagePrevious in topicNext in topicPrevious by same authorNext by same authorPrevious page (November 2005, week 2)Back to main VANAGON pageJoin or leave VANAGON (or change settings)ReplyPost a new messageSearchProportional fontNon-proportional font
Date:         Fri, 11 Nov 2005 13:55:16 -0500
Reply-To:     Kenneth Wilford <kenwilfy@COMCAST.NET>
Sender:       Vanagon Mailing List <vanagon@gerry.vanagon.com>
From:         Kenneth Wilford <kenwilfy@COMCAST.NET>
Subject:      Re: Fuel tank cross over tube
Comments: To: John <kayakjr@JUNO.COM>
In-Reply-To:  <20051111.095125.26022.24784@webmail30.lax.untd.com>
Content-Type: text/plain; charset="us-ascii"

Most of the time if you have a fuel smell after you fill up with gas, or if you have a leak on the ground after filling up, then one of the plastic "T"s this plastic pipe is broken (about 80% of the time). Most folks who are doing this job don't want to do it again any time soon so they replace the plastic pipe even if it might not need it at the time because they realize that it only takes a couple of minutes to put the new pipe in when the tank is out vs. dropping the whole tank again to replace it later.

If you have already done your repair, and you are not experiencing a fuel smell on fill up or leakage, I would not worry about it until you start to have a problem.

Hope this helps. PS, the plastic pipe is going up in price again to around $53. Thanks VW!

Thanks, Ken Wilford John 3:16 http://www.vanagain.com http://www.strictlyvwauctions.com http://www.eurovan.org http://www.vwcabrio.org Phone: (856)-327-4936 Fax: (856)-327-2242

-----Original Message----- From: Vanagon Mailing List [mailto:vanagon@gerry.vanagon.com] On Behalf Of John Sent: Friday, November 11, 2005 12:51 PM To: vanagon@GERRY.VANAGON.COM Subject: Fuel tank cross over tube

I need to replace the fuel tank vent lines and such on my "new" Vanagon - I noticed all the kits from the vendors include the cross-over plastic tube/pipe is on top of the tank, as well as a new o-ring for the fuel gage sender. I did not replace this pipe when I did this procedure on my old van. Is it really necesarry to replace this cross over pipe and the o-ring for the fuel tank sender? The plastic pipe adds $35+ dollers vs just lines and seals. Just wondering what people's personal expereince is in this area. John 87 Westy Weekender

The next thing to being clever is being able to quote someone who is -Mary Pettibone Poole


Back to: Top of message | Previous page | Main VANAGON page

Please note - During the past 17 years of operation, several gigabytes of Vanagon mail messages have been archived. Searching the entire collection will take up to five minutes to complete. Please be patient!


Return to the archives @ gerry.vanagon.com


The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.

Any profits from list compilations go exclusively towards the management and operation of the Vanagon mailing list and vanagon mailing list web site.