Vanagon EuroVan
Previous messageNext messagePrevious in topicNext in topicPrevious by same authorNext by same authorPrevious page (August 2006, week 4)Back to main VANAGON pageJoin or leave VANAGON (or change settings)ReplyPost a new messageSearchProportional fontNon-proportional font
Date:         Thu, 24 Aug 2006 10:25:56 -0700
Reply-To:     Zoran Mladen <zmaninco@YAHOO.COM>
Sender:       Vanagon Mailing List <vanagon@gerry.vanagon.com>
From:         Zoran Mladen <zmaninco@YAHOO.COM>
Subject:      Re: Strange no start problem - still having issues
In-Reply-To:  <44D365F2.7060404@cox.net>
Content-Type: text/plain; charset=iso-8859-1

Hey folks,

Thanx for the first round of help, but the difficulty continues. We are still getting no ground from the ECU. We have swapped in two other ECUs - although we are not sure they are good, I find it hard to believe I have gotten three bad ECUs.

We also replaced the wire harness and checked this wire to be sure it is working well.

If we jump the fuel pump relay, the car will start and runs fine. This tells me the hall sender is working fine. I was wondering about one thing. I know the fuel injection system is setup to stop the fuel pump running when the engine is not running but the key is still on - so if you are in a rollover and the key is still on but the engine cuts off, the fuel pump will also stop. How is this done? It seems that the ECU simply does not know to tell the fuel pump to run...like it thinks the engine is not turning.

Also, this may be important, the fuel pump should run for about a second when you turn the key on. Not happening on this Vanagon. Simply no ground from the ECU to the fuel pump relay ever.

Other items that have been changed: ignition coil, ignition switch, distributor. Like I said, when jumping the relay, it starts and runs great. Just can't get that darn ground from the ECU.

Help...running out of ideas...

Z

Mark Drillock <mdrillock@cox.net> wrote: Zoran, you are right, the Bentley diagram for 88-89 has it wrong. I wrote about this several months ago. Page 97.206 has the correct wiring for the 2 engine relays, shown as 1990+. The fuel pump relay also provides power to the injectors, pulsed by the ECU when the ECU pulses the ground side.

You have one thing wrong though. The power to turn on both the relays comes from the key switch but the fuel pump only runs when the ECU provides ground to it on pin 85. The other relay(ecu relay) always has ground on it's pin 85 so as soon as the key is turned on it turns on. The fuel pump relay needs the key on too but then also needs the ECU to provide ground on it's pin 85. If the fuel pump relay has power on it's pin 86 but does not run for a couple seconds when the key is turned on, the ECU may be at fault by not providing the ground on pin 85. Or the relay could be bad, or the wire from the ecu to pin 85 may be bad. Remember that this is not true ground, but ground through a transistor inside the ECU, only when the ECU turns on the transistor.

Mark

Zoran Mladen wrote:

> Hi folks! > > Having a strange issue with an 88 Vanagon non-westy non-syncro. It did not want to start. We replaced the fuel injection relay and it started and ran nicely. We drove it about 5 miles and it died and refused to start. It is not getting fuel pressure and no fuel injector pulsing. Looking at the wiring diagram in Bentley we found an error. The Bentley claims that the "juice" for the injectors (which is delivered when the key is on) comes from the fuel injection relay. This is not true! It comes from the fuel pump relay. We verified that with a couple old harnesses as well. > > At any rate, if we jumper (30 to 87) the fuel pump relay, we get fuel pressure, the fuel injectors pulse, and the car starts right up. Doing more tests, we know that the fuel injectors are getting the proper ground signal from the ECM - hence the hall sender and all wiring is working - but not getting juice, which is triggered by a hot wire to the relay coming from the ECU. The ground is at the relay, but no juice to activate the relay. > > Also, with the car running (with the fuel pump relay jumpered), the fuel injection relay gets very hot. > > At this point, I am thinking there is either a problem in the ECU or in the harness. Perhaps some melted wires, causing the "no juice" from the ECU as well as causing the fuel injection relay to get hot. Do folks agree? Disagree? Love to hear opinions. > > Thanx! > > Z > > > --------------------------------- > How low will we go? Check out Yahoo! Messenger’s low PC-to-Phone call rates. >

--------------------------------- Talk is cheap. Use Yahoo! Messenger to make PC-to-Phone calls. Great rates starting at 1¢/min.


Back to: Top of message | Previous page | Main VANAGON page

Please note - During the past 17 years of operation, several gigabytes of Vanagon mail messages have been archived. Searching the entire collection will take up to five minutes to complete. Please be patient!


Return to the archives @ gerry.vanagon.com


The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.

Any profits from list compilations go exclusively towards the management and operation of the Vanagon mailing list and vanagon mailing list web site.