Date:         Thu, 24 Aug 2006 11:21:26 -0700
Reply-To:     Mark Drillock <drillock@EARTHLINK.NET>
Sender:       Vanagon Mailing List <vanagon@gerry.vanagon.com>
From:         Mark Drillock <drillock@EARTHLINK.NET>
Subject:      Re: Strange no start problem - still having issues
Comments: To: Zoran Mladen <zmaninco@YAHOO.COM>
In-Reply-To:  <20060824172557.93054.qmail@web33503.mail.mud.yahoo.com>
Content-Type: text/plain; charset=us-ascii; format=flowed

Zoran, I wonder if you are working with the right relay. The fuel pump relay is the one with the fewest wires going to it and the fuel pump should run constantly with the relay socket jumped between pins 30 and 87. If this is true, you have the right relay.

If so, you should make a set of extension wires for the relay. 4 wires, with a male spade on one end and female spade on the other end of each. 3 or 4 inches for each wire is all you need for 3 of the wires. Make the other at least 12 inches long. Then plug the female ends onto the relay and put the male ends in the relay socket, using the longer one for pin 85. Be very careful since one relay socket hole is ALWAYS live and there is no fuse for any of the fuel injection wiring!

With these extension wires you can measure the voltage on each leg and see if the ECU is providing the pseudo ground on pin 85. You can test the system by removing the extension wire from pin 85 of the relay socket, but leave it plugged into pin 85 of the relay. Then with the longer wire's male end touching bare metal on the body, you can manually ground pin 85 of the relay while the other 3 extensions are still in place. With the key off, nothing should happen. With the key on, the relay should click and the fuel pump should run each time you touch the male end to bare metal.

Let us know what happens.

Mark

Zoran Mladen wrote:

> Hey folks, > > Thanx for the first round of help, but the difficulty continues. We are still getting no ground from the ECU. We have swapped in two other ECUs - although we are not sure they are good, I find it hard to believe I have gotten three bad ECUs. > > We also replaced the wire harness and checked this wire to be sure it is working well. > > If we jump the fuel pump relay, the car will start and runs fine. This tells me the hall sender is working fine. I was wondering about one thing. I know the fuel injection system is setup to stop the fuel pump running when the engine is not running but the key is still on - so if you are in a rollover and the key is still on but the engine cuts off, the fuel pump will also stop. How is this done? It seems that the ECU simply does not know to tell the fuel pump to run...like it thinks the engine is not turning. > > Also, this may be important, the fuel pump should run for about a second when you turn the key on. Not happening on this Vanagon. Simply no ground from the ECU to the fuel pump relay ever. > > Other items that have been changed: ignition coil, ignition switch, distributor. Like I said, when jumping the relay, it starts and runs great. Just can't get that darn ground from the ECU. > > Help...running out of ideas... > >


Back to: Top of message | Previous page | Main VANAGON page

Please note - During the past 17 years of operation, several gigabytes of Vanagon mail messages have been archived. Searching the entire collection will take up to five minutes to complete. Please be patient!


Return to the archives @ gerry.vanagon.com


The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.

Any profits from list compilations go exclusively towards the management and operation of the Vanagon mailing list and vanagon mailing list web site.