At 05:30 PM 1/8/2007, Pensioner wrote... >and about 5" or so up each side of the "U". Noticing that the water >level >in each side of the U is essentially the same, mark the tubing with >some >tape at the water level on the open side of the U (not connected to >the >tank). Put another piece of tape 11 inches +/- 1/16" above this >mark. You >now have a 11 in-H20 calibrated tool Not quite. 11" pressure is an 11" differential when measured with a manometer. You should have enough of a "U" so there's always some water on the "low" side. If the water goes up on one side by 11", the other side will lower by 11". Your description will result in a pressure of 22" H20. You want to make a mark at 5.5" above the static level, which is the same as an 11" differential. |
Please note - During the past 17 years of operation, several gigabytes of
Vanagon mail messages have been archived. Searching the entire collection
will take up to five minutes to complete. Please be patient!
Return to the archives @ gerry.vanagon.com
The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.