Vanagon EuroVan
Previous messageNext messagePrevious in topicNext in topicPrevious by same authorNext by same authorPrevious page (March 2007, week 3)Back to main VANAGON pageJoin or leave VANAGON (or change settings)ReplyPost a new messageSearchProportional fontNon-proportional font
Date:         Mon, 19 Mar 2007 23:40:41 -0700
Reply-To:     Philip Zimmerman <philzimm1@OBERON.ARK.COM>
Sender:       Vanagon Mailing List <vanagon@gerry.vanagon.com>
From:         Philip Zimmerman <philzimm1@OBERON.ARK.COM>
Subject:      Re: parts list for radiator replacement on 1988 Westy
In-Reply-To:  <200703200407.l2K47crt009430@oberon.ark.com>
Content-Type: text/plain; charset=US-ASCII; format=flowed

Date: Mon, 19 Mar 2007 20:43:39 -0700 From: Shawn Wright <vwdiesels@GMAIL.COM>

Hi Phil,

Thanks for the detailed account on your rad replacement. I tried to replace mine with one from CIP1 last year, but they sent me the wrong unit (one from a Jetta, and I had to argue with them over it!) Anyway, since I needed to get back on the road, I flushed the old one, and put it back in. So now I'm driving with the original '88 rad with nearly 400k on it, albeit well flushed now since removing from the van and hosing it out well. I don't know yet if it performs any better since the flushing, since we haven't had any heat or long hills to climb since then.

But I was wondering what prompted you to replace yours? Did it leak, or just lose cooling efficiency? Mine has seen lots of salt, so plenty of corrosion on the fins, and I imagine Al oxide won't help the heat transfer. If your replacement was for heat issues, did you notice an improvement with the new one? Last summer over the Rockies, I had the coolant LED flash with the gauge almost pegged by the time I hit the top of Rogers Pass. I am missing the air deflector flaps, so I should try to rebuild those too... ------------------- Hi back Shawn,

Sorry to hear of the Bad Karma at CIP1. My usual experience with them is they're out of stock or have only one of a pair I require.... I'm gonna miss BOW_WOW in Victoria. More Bizz for the local VW Stealer Parts guy.... They will miss BOW_WOW too...

Re: Replacing Rad, a couple of whys and why-nots?

Years of watching the temp gauge while climbing steep roads on hot daze! Gauge never went full hot and no red flashing light. Rad-fan on low, usually stabilized the temp rise. High Fan occasionally kicked-in on really steep long climbs with hot outside temps. Installed the lower temp fan thermostat. Fan kicked-in a bit sooner and kept the temps from rising as far or fast on a moderate climb. My gut-instinct was telling me the Rad was becoming clogged?

I had the Rad out while replacing the plastic pipes and doing the usual 300,000 Km PNW rust stabilization on the Rad-Fan Housing. Took a look inside the Rad through the In/Out Rad hose flanges. Cannot see a whole lot but sure enough, the cores I could see were approximately 50% closed-up with hard baked-on corrosion/scale. Back flushed with a water hose. No significant gunk came out.

Gave the exterior a close inspection. Some minor surface corrosion, a few suspect pits. Power washed to blow a bazillion bugs out of the fins. Looked Ok. Considered having the Rad chemically cleaned. The $150 for cleaning, flow/pressure testing just didn't sit well, with the high mileage I had on this Rad. Replaced with a German aftermarket one from BOW_WOW.

Wow, does a new Rad ever cool great! Replaced the Thermostat with a new, pre-tested in the kitchen one, 85 C. said my lab thermometer. Temp gauge reads consistently a bit lower than before Rad replacement. Temps still rise when the engine is working hard but not near as high as before. When the Rad-Fan kicks-in the temps immediately stabilize.

Did a destructive autopsy on the old Rad. Sure enough, the core was evenly clogged top to bottom. A few of the core-passes were near 100% closed-shut from corrosion/scale. Wouldn't pass much compressed air at 120#. This Rad appeared original to the Van. Sure was in good shape for the mileage and age. Was serviced at the Dealer by the PO and has been obsessively serviced by this car-guy. So assume at a minimum, coolant changes every two years and only VW Spec Coolant has passed through her cooling tubes. Only PNW soft water too. Chlorine and Fluoride unfortunately were included as city tap water was used. Vanagons don't suffer tooth-decay and Chlorine isn't good for anything but white shirts, table cloths and killing black-molds....

regards

Phil Z. ----------------


Back to: Top of message | Previous page | Main VANAGON page

Please note - During the past 17 years of operation, several gigabytes of Vanagon mail messages have been archived. Searching the entire collection will take up to five minutes to complete. Please be patient!


Return to the archives @ gerry.vanagon.com


The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.

Any profits from list compilations go exclusively towards the management and operation of the Vanagon mailing list and vanagon mailing list web site.