There is a little metal clip that holds the heater cable on the body of the front heater valve. That clip is likely rusted and fell off. The cable therefore just moves freely and is not able to close the valve. Could also be the valve arm rusting off, but more likely the clip. Pascal '84 Westy -----Original Message----- From: Vanagon Mailing List [mailto:vanagon@gerry.vanagon.com] On Behalf Of Jack R. Sent: May 24, 2007 12:28 PM To: vanagon@GERRY.VANAGON.COM Subject: Heater always blows hot My 84 Vanagon seems to always blow hot air from the heater vents, I have to move the top two all the way left, the #3 all the way right, and the #4 all the way left, to minimize the air flow.
If I move all 4 to the left, I get very warm air (almost hot), coming from the floor vents.
Never had this problem before?
Thanks in advance for the guidance!
Jack R. N. of Detroit 84 Westy, newer 2.1L, new Radiator and new coolant pipes. |
Please note - During the past 17 years of operation, several gigabytes of
Vanagon mail messages have been archived. Searching the entire collection
will take up to five minutes to complete. Please be patient!
Return to the archives @ gerry.vanagon.com
The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.