A couple of comments: In Westies, the regulator is connected directly to the service valve (on/off valve.) The original regulator (square diaphrams) had a box to protect it. New regulators have the white plastic cover, so that box is not needed. The vents MUST point DOWN. This is important. There are regulators where stage one and stage two point different ways--do not use them! The whole point of a vent is to let any condensation drip out--so it must point down. The cover is to protect the vent. The Westies (and apparently the ASIs) have a bash plate or guard, which protects the valves, regulator, etc, from gravel, etc, and also adds protection to the vents beyond the covers. Here, for example, is a regulator that you do NOT want to install on a horizontal tank: http://www.campingworld.com/browse/skus/index.cfm?skunum=26059 because when installed horizontally, the vents will not point down. Richard Boulder |
Please note - During the past 17 years of operation, several gigabytes of
Vanagon mail messages have been archived. Searching the entire collection
will take up to five minutes to complete. Please be patient!
Return to the archives @ gerry.vanagon.com
The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.