Vanagon EuroVan
Previous messageNext messagePrevious in topicNext in topicPrevious by same authorNext by same authorPrevious page (July 2007, week 2)Back to main VANAGON pageJoin or leave VANAGON (or change settings)ReplyPost a new messageSearchProportional fontNon-proportional font
Date:         Tue, 10 Jul 2007 20:47:34 EDT
Reply-To:     Kjmmensing@AOL.COM
Sender:       Vanagon Mailing List <vanagon@gerry.vanagon.com>
From:         Jeff Ensing <Kjmmensing@AOL.COM>
Subject:      Re: Recalls
Comments: To: pbrattan@GMAIL.COM
Content-Type: text/plain; charset="US-ASCII"

In a message dated 7/10/2007 8:11:35 P.M. Eastern Daylight Time, pbrattan@GMAIL.COM writes:

I just called VW and asked them to check my VIN for recalls. They told me that the recall on the fuel line components has not been done. I then called a local VW dealer who works on Vanagons (VW of Santa Monica,) and they said I was eligible for the recall work! They said their cutoff is 20 years! They said I should bring it in for inspection, and if they have the parts, they'll do it the same day; if not, they'll order them for me and I'll bring Scarlett back when they get them.

Woo-hoo! If all goes well, they will replace my fuel line for free! I also contacted the P.O. who was very conscientious about preventative maintenance, and he never had the fuel lines replaced. And I would never have known anything about this potential danger if not for this forum! Thanks. Patti

Patti You should know that the Recall does not cover every fuel line. The recall was to address the clamps at the injectors and fuel rails leaking when cold. Some (depending on VIN) get all new injectors , new rails and the lines from the fuel rails to the regulator and tee that leads to the pump only.

You will still need the line from the tee to the plastic connector on the fire wall , the plastic connector on the firewall , and the line from the regulator to the metal return pipe. THE PLASTIC CONNECTOR IS THE MOST DANGEROUS PART ! especially after someone starts replacing lines and pulls on it and cracks it.

I would recommend asking to have these additional line's and fire wall fitting replaced at the same time with the "new " factory clamps on each connection.

Ask for the old injectors too for spares. They may say they have to save them incase VW calls for them but VW does not call for these things any more since they know they are a recall.

Jeff E. Atlanta , Ga. 87' Westy "weekender"

************************************** See what's free at http://www.aol.com.


Back to: Top of message | Previous page | Main VANAGON page

Please note - During the past 17 years of operation, several gigabytes of Vanagon mail messages have been archived. Searching the entire collection will take up to five minutes to complete. Please be patient!


Return to the archives @ gerry.vanagon.com


The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.

Any profits from list compilations go exclusively towards the management and operation of the Vanagon mailing list and vanagon mailing list web site.