On 7/19/07, Dennis Haynes <d23haynes57@hotmail.com> wrote: > > The sure power isolator or smart relay is actually a voltage controlled > relay. It connects the two battery banks when either one is being charged. > When the charge source stops and the voltage returns to a battery only > state, the banks are again isolated.
In addition the Surpower 1315 gives priority to the starting battery, charges it first before charging the aux battery. But it can be wired to use the aux battery in parallel with the starting battery either automatically or with a switch added to the circuit. |
Please note - During the past 17 years of operation, several gigabytes of
Vanagon mail messages have been archived. Searching the entire collection
will take up to five minutes to complete. Please be patient!
Return to the archives @ gerry.vanagon.com
The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.