Date:         Mon, 27 Aug 2007 03:29:15 -0500
Reply-To:     Matt Roberds <mattroberds@COX.NET>
Sender:       Vanagon Mailing List <vanagon@gerry.vanagon.com>
From:         Matt Roberds <mattroberds@COX.NET>
Subject:      Re: Question on Surepower 1315 Install
Comments: cc: Loren Busch <starwagen@GMAIL.COM>
In-Reply-To:  <20070826185441.MVAZ15942.fed1rmmtai104.cox.net@fed1rmimpi02.cox.net>
Content-Type: TEXT/PLAIN; charset=US-ASCII; format=flowed

> From: Loren Busch <starwagen@GMAIL.COM> > Date: Sun, 26 Aug 2007 10:08:44 -0700 > > Has anyone found a good way to cover/protect the terminals on top > where the two batteries connect?

Right angle insulators for battery cables that bolt to studs like this do exist in the world. I've used these on a student-built hybrid car project and they work well: http://www.delcity.net/delcity/servlet/catalog?parentid=1033&page=1

One minor problem is that Del City has a $25 minimum order and the the insulators are less than a buck each. You may be able to find them locally - I'd try maybe an RV shop, a battery *distributor* (not just a place that sells batteries, but the warehouse that is supplying all of the local garages - Interstate Batteries often has one in larger cities), or maybe a heavy equipment shop (bulldozers, backhoes, stuff like that). The battery distributor or heavy equipment shop may or may not sell "retail", but they may be able to tell you who can sell you what you want locally.

Another option is to fabricate your own out of something like heater hose or big fuel line. You may have to experiment a bit to find the right diameter, but the basic idea is to take a piece of heater hose maybe 2" long and slit it down one side with a knife. Then, with the cable bolted onto the stud, slip the hose over the cable, and slide it down so it covers the stud. (It may help to make the slit wider where it goes over the stud.) Then throw a couple of zip ties around the hose to cinch it to the cable. This is a good place to re-use an old cruddy hose you pulled off the van - unless it's totally shot, you can probably cut a couple of inches of good-enough hose out of it. If you have or can get some of that split corrugated plastic tubing that is made for bundling wires into a harness, it can be used in the same way.

Yet another option is to get happy with electrical tape. This is a major pain in the butt when you have to take the connection apart later, but electrical tape is universally available at 24-hour Wally Worlds, truck stops, etc.

Standard disclaimers apply; I don't get money or other considerations from any companies mentioned.

Matt Roberds


Back to: Top of message | Previous page | Main VANAGON page

Please note - During the past 17 years of operation, several gigabytes of Vanagon mail messages have been archived. Searching the entire collection will take up to five minutes to complete. Please be patient!


Return to the archives @ gerry.vanagon.com


The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.

Any profits from list compilations go exclusively towards the management and operation of the Vanagon mailing list and vanagon mailing list web site.