Date:         Mon, 17 Mar 2008 10:30:23 -0700
Reply-To:     Keith Ovregaard <kovregaard@COMCAST.NET>
Sender:       Vanagon Mailing List <vanagon@gerry.vanagon.com>
From:         Keith Ovregaard <kovregaard@COMCAST.NET>
Subject:      Re: Fuel Tank Weirdness
Content-Type: text/plain; charset=US-ASCII; format=flowed; delsp=yes

Thanks guys for your feedback.

I was hoping that I would not have to remove the tank, but It does seem that's where the problem exists. Dropping a syncro tank does not sound like fun and I think I'd have to get my mechanic to handle that task. There goes more $$!!!

The filler and vent hose that runs to the filler neck are sealed well at that end. As Ken mentioned, the question is what's happening at the other end of that vent hose. If there is a kink and/or bad seal where it enters the top of the tank, that would certainly explain the poor filling and fumes. BTW, all of the fuel station pumps I've ever used have had trouble getting the last few gallons in the tank, so it's not the pumps fault.

One thing I have not tried is to disconnect the vent hose at the filler and blow air into it to see if there is good flow into the tank. There should be air coming back out the filler when I do that, right?

Oh, and thanks to Jeff for bringing over his syncro. We found out that his WBX'r had the bottom vent hose of the charcoal filter exhaust to atmosphere, not into air cleaner, Bentley mentioned. Also, his Subaru conversion charcoal filter vents to atmosphere, so no issues there. Must be that the non-syncro models vented to the air cleaner for some odd reason.

Keith O 90 Westy Syncro (VikingWagen)

On Mar 16, 2008, at 9:04 PM, Automatic digest processor wrote:

> Date: Sun, 16 Mar 2008 19:04:52 -0800 > From: Kim Springer <kimspringer@RCN.COM> > Subject: Re: Fuel Tank Weirdness > > I would drop the tank, give it a reseal kit and blow out the vent > line that > goes from the top of the filler neck and into the top of the tank. > > When you fill the tank, there is no perfect seal from the nozzle on > the > pump, so air should be able to vent while filling it up. At the > bottom of > the fillier neck, mine has (about) a 3/4" ball in a cage that's part > of the > filler neck, to keep fuel from backing up the filler neck (I guess > on hard > corners or roll-overs). I suppose it could be that this ball is > stuck in > some way, blocking the entrance of fuel at the bottom of the filler > neck. > > Can't think of anything else, unless you are using the same pump at > the same > station and it has to do with the pump and not your van? > > Kim


Back to: Top of message | Previous page | Main VANAGON page

Please note - During the past 17 years of operation, several gigabytes of Vanagon mail messages have been archived. Searching the entire collection will take up to five minutes to complete. Please be patient!


Return to the archives @ gerry.vanagon.com


The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.

Any profits from list compilations go exclusively towards the management and operation of the Vanagon mailing list and vanagon mailing list web site.