Date:         Wed, 8 Oct 2008 14:36:36 -0700
Reply-To:     David Kao <dtkao0205@YAHOO.COM>
Sender:       Vanagon Mailing List <vanagon@gerry.vanagon.com>
From:         David Kao <dtkao0205@YAHOO.COM>
Subject:      Re: Technical question re: Injector firing signal
Comments: To: "B.J.R." <beer_eighty@YAHOO.COM>
In-Reply-To:  <955156.38085.qm@web83601.mail.sp1.yahoo.com>
Content-Type: text/plain; charset=us-ascii

You may want to check the two relays that are often the cause of this kind of problem, i.e. no signal to injectors. One of them is called fuel pump relay and the other power control relay. Do not swap the two with each other. Any of the two being defective can result in a same symptom. So you will want to find a new one then try to replace one at a time to identify the bad one.

One of the two injector leads is supplied with +12v and the other will be grounded by the ECU when the ECU fires the injector. If the ECU is defective it may not be sending the signal to ground the 2nd wire of the injector. If you get sparks that means the Hall Effect Unit is working in sending the signal to the ECU. If the ECU is not defective then the two relays are more likely to be faulty (one of them).

This was discussed many times before. Maybe this is why no one jumped out to point this out. Good luck.

David

--- On Wed, 10/8/08, B.J.R. <beer_eighty@YAHOO.COM> wrote:

> From: B.J.R. <beer_eighty@YAHOO.COM> > Subject: Re: Technical question re: Injector firing signal > To: vanagon@GERRY.VANAGON.COM > Date: Wednesday, October 8, 2008, 11:04 AM > I do not know. > > Could you be more specific? IE: how do I test? > > Only wire I see directly to the ECU in the wiring diagram > is terminal #1 at the ECU. > > AND > > if there is no signal, does that mean bad Distributer or > bad signal generator (hall distributor)?? > > Does it matter, because i believe ONLY entire rebuilt > distributrors are available, not rebuild kits. > > > ----- Original Message ---- > From: Eric Ley <eric_ley@hotmail.com> > To: B.J.R. <beer_eighty@YAHOO.COM> > Sent: Wednesday, October 8, 2008 9:45:22 AM > Subject: Re: Technical question re: Injector firing > signal > > do you have signal for the distrubitor ??? need to tel the > computer when to > send signal to the injectors > > > --\


Back to: Top of message | Previous page | Main VANAGON page

Please note - During the past 17 years of operation, several gigabytes of Vanagon mail messages have been archived. Searching the entire collection will take up to five minutes to complete. Please be patient!


Return to the archives @ gerry.vanagon.com


The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.

Any profits from list compilations go exclusively towards the management and operation of the Vanagon mailing list and vanagon mailing list web site.