At 05:58 PM 1/25/2010, John Rodgers wrote: >This thread brings to mind having seen somewhere something about using a >relay(relays) to reduce the load on the front heater control switch. > >Anyone have a link showing this??? Use the high-speed position on the switch to drive the 86 terminal on a 20-amp relay; ground the 85 terminal. Use the 87 terminal to drive the high-speed wire to the fan. On a 2.1l feed the 30 terminal from the switch feed wire, but on a 1.9l run a separate fused circuit to feed the 30 terminal. The two lower-speed positions aren't overloaded so they don't need any help. Yours, D |
Please note - During the past 17 years of operation, several gigabytes of
Vanagon mail messages have been archived. Searching the entire collection
will take up to five minutes to complete. Please be patient!
Return to the archives @ gerry.vanagon.com
The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.