At 12:44 PM 4/9/2010, Scott Chapman wrote: >I read that the copper pipes to the propane tank are 8mm? > >In that case, I'm wondering if one of these would be any use in flaring >the pipe after I cut off a couple inches to make it work with the new >regulator on the new tank? Dear Scott, For cutting the tool of choice would be a tubing cutter, likely a midget one for close-quarters use. You roll it around the tube while gradually advancing a hard thin swaging disk into the tube, which soon parts off leaving a large burr on the inside to be reamed out. 8 mm is very close to 5/16 inch. Since this is a US tank with a US regulator and US refrigerator (and stove?) I would expect the plumbing to be US standard as well. Yours, David |
Please note - During the past 17 years of operation, several gigabytes of
Vanagon mail messages have been archived. Searching the entire collection
will take up to five minutes to complete. Please be patient!
Return to the archives @ gerry.vanagon.com
The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.