Vanagon EuroVan
Previous messageNext messagePrevious in topicNext in topicPrevious by same authorNext by same authorPrevious page (August 2010, week 1)Back to main VANAGON pageJoin or leave VANAGON (or change settings)ReplyPost a new messageSearchProportional fontNon-proportional font
Date:         Sun, 1 Aug 2010 15:43:35 -0500
Reply-To:     Michael Sullivan <sandwichhead@GMAIL.COM>
Sender:       Vanagon Mailing List <vanagon@gerry.vanagon.com>
From:         Michael Sullivan <sandwichhead@GMAIL.COM>
Subject:      Re: Need help with leak at fitting on AC condenser
Comments: To: Dvdclarksn@aol.com
In-Reply-To:  <dbf01.754aa427.3987295c@aol.com>
Content-Type: text/plain; charset=ISO-8859-1

< I'd really like to charge it one more time and be done with this project of epic proportions>

I'm gonna fix a leak soon and wonder if you think it would have been worth it to pay someone else to do it. Michael in San Antonio 91GL Weekender AT 2.1L 'Gringo'

On Sun, Aug 1, 2010 at 2:47 PM, David Clarkson <Dvdclarksn@aol.com> wrote:

> I have had great success in getting my ac running super cool (34 deg. F. at > the center vent). All is well until the freon leaks out at the larger of > the two connections where the hose connects to the condenser. I have put > dye > in the system and checked for any other leaks all over with a hydrocarbon > sniffer-none. I have tried all different combinations of o-rings, different > sizes and even 2 o-rings and finally went back with the factory o-ring > after all sorts of o-ring swelling (stop leak) chemicals introduced when > recharging. I inspected it again with UV light and found that it is > definitely > leaking at this one point. Cleaned up the dye here and gently turned the > nut > on the fitting about 1/8 of a turn. I have been scared to crank on this > too hard and have the threaded portion break off and then have to replace > the > condenser. Has anyone else on the list had a leak at this connection? I > feel really confident that it is not leaking from a crack at the fitting > where it connects to the condenser or from where the hose crimp is. How > much > force should I use when tightening this? Am I likely to break off the > fitting > from over torqueing? R134A isn't expensive but not exactly cheap either. > Dang, I am so close to having this fixed. Hoping cooler heads will have > some > suggestions here. I'd really like to charge it one more time and be done > with this project of epic proportions. Thanks list for all your help. > > David Clarkson > 1990 Westfalia >


Back to: Top of message | Previous page | Main VANAGON page

Please note - During the past 17 years of operation, several gigabytes of Vanagon mail messages have been archived. Searching the entire collection will take up to five minutes to complete. Please be patient!


Return to the archives @ gerry.vanagon.com


The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.

Any profits from list compilations go exclusively towards the management and operation of the Vanagon mailing list and vanagon mailing list web site.