At 01:36 PM 11/8/2010 -0500, Jeff Lincoln wrote: >So I did a little research of list archives and the Samba forum - I saw some >mention of CPVC but no definitive answers about it. Without starting a big >debate please - can someone tell me why that might not work? I know the heat >ratings look like they would be high enough but those are tested with water. Max service temp of CPVC pipe is 200F with an 80% pressure derating. Boiling point of 50/50 glycol antifreeze mix is 265F. I'd call that a definite never, myself. http://www.harvel.com/piping-cpvc-derating.asp Yrs, d |
Please note - During the past 17 years of operation, several gigabytes of
Vanagon mail messages have been archived. Searching the entire collection
will take up to five minutes to complete. Please be patient!
Return to the archives @ gerry.vanagon.com
The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.