At 07:21 AM 12/17/2010, VWQ47 wrote: >Has anyone experienced an issue like this? Where should I look? I'd >appreciate any wisdom people have. Check your switches, unplugged. Column switch As it sits: continuity from 56 to one of 56a or 56b; no other continuity from any terminal to any other. Full click and release: change between 56a and 56b, no other change. Partial pull: 30 to 56a (and to 56 depending on above). No other change. Panel switch: Off: no continuity any terminal to any other except 58b to 58 (panel dimmer) and 30-30. First click: either 30 terminal to 58, and 58b through the panel dimmer resistor. No other continuities. Second click: as above plus X terminal to 56 terminal. No other continuities. Report results. If switches are ok we'll look at wires. Yrs, d |
Please note - During the past 17 years of operation, several gigabytes of
Vanagon mail messages have been archived. Searching the entire collection
will take up to five minutes to complete. Please be patient!
Return to the archives @ gerry.vanagon.com
The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.