> But if they don't open the bleed screw ALL THE WAY = > before they try to fill, it can pressure lock and then you have a harder ti= > me if the guy doesn't know how the pressure relief valve works. That's the key. For the auto-stop valve, it must be fully open. But the reason propane jockeys don't know to do that is the typical (99.9% of tanks) bleeder valve needs to be open just a crack to vent when they fill the tank. When they see propane from the bleeder, it is full. For the auto-stop to shut off the valve automatically, it must be fully open. So two reasons to replace the auto-stop with a regular fill valve and a regular bleeder valve: (1) the auto-stops are very old and may be failing, and (2) propane guys will know how to fill the tank without coaching. Richard |
Please note - During the past 17 years of operation, several gigabytes of
Vanagon mail messages have been archived. Searching the entire collection
will take up to five minutes to complete. Please be patient!
Return to the archives @ gerry.vanagon.com
The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.