Date:         Sat, 13 Aug 2011 15:00:52 -0500
Reply-To:     jaime forero <jforero@SBCGLOBAL.NET>
Sender:       Vanagon Mailing List <vanagon@gerry.vanagon.com>
From:         jaime forero <jforero@SBCGLOBAL.NET>
Subject:      Re: AC cutting out momentarily
Comments: To: Larry Alofs <lalofs@GMAIL.COM>
In-Reply-To:  <CA+r=Jhr7-bx0GUe83D7ziZJNYqRCH_toENVr=bXxJre2yfSaLg@mail.gmail.com>
Content-Type: text/plain; charset="koi8-r"

I think that is the way to go, soldering but I still have the question about using a heavier gauge wire. Cheers Jaime

_________________ Jaime Forero jforero@sbcglobal.net Siempre Adelante!!! ÷óåçäá ÷ðåò³ä!

-----Original Message----- From: Vanagon Mailing List [mailto:vanagon@gerry.vanagon.com] On Behalf Of Larry Alofs Sent: Saturday, August 13, 2011 1:05 PM To: vanagon@GERRY.VANAGON.COM Subject: Re: AC cutting out momentarily

I replaced the fusible link setup with a 50 A fuse and holder that I got in the automotive audio section of W*lmart, I think. More importantly, I replaced the old corroded crimp-on wire terminals with new hefty ones and soldered them on after scraping the wires thoroughly.

Larry A.

On Sat, Aug 13, 2011 at 12:59 PM, David Clarkson <dvdclarksn@aol.com> wrote: > šI used the same gauge wire as I didn't want to do anything that might change resistance since that is what seemed to cause the excess build up of heat. Someone will probably correct me here if this theory doesn't hold water. It took 20 years for enough oxidation/corrosion to cause the problem so I used the same type wire but didn't use the same type ring connector as the copper OEM seemed more prone to oxidation. I replaced the fusible link with a junk yard part and bet that part is no longer available. I'm sure that there is another fuse option (50amp right?) or suitable automotive circuit breaker that could be substituted. > > David Clarkson > 90 Westy > > > > > > > > -----Original Message----- > From: Jaime Forero &lt;jforero@sbcglobal.net&gt; > To: dvdclarksn &lt;dvdclarksn@AOL.COM&gt;; vanagon &lt;vanagon@GERRY.VANAGON.COM&gt; > Sent: Sat, Aug 13, 2011 12:14 pm > Subject: RE: AC cutting out momentarily > > > > > Did you use the same gauge wire?? šI am tempted to go to a heavier gauge > wire for the wire going to the fusable link (well I really now have > resettable fuse). > Jaime > -----Original Message----- > From: Vanagon Mailing List [mailto:vanagon@gerry.vanagon.com] On Behalf Of > David Clarkson > Sent: Saturday, August 13, 2011 10:12 AM > To: vanagon@GERRY.VANAGON.COM > Subject: Re: AC cutting out momentarily > > šBTDT- the corrosion can cause increased resistance and pop the fusable > link. This happened simultaneously with the meltdown of my trinary switch. I > replaced several wires and connectors along with the switch and have had no > other heat build up or meltdowns. This was still a very easy project as > vanagon AC projects go. One of many over about 2-3 years of troubleshooting > the AC in my rig. In the end it was all worth it as I have had 34 deg. vent > temps once the system really gets going good. > > David Clarkson > 90 Westy-cool running! > > > > > > -----Original Message----- > From: Gregory Smith &lt;gfs@GREGORYFSMITH.COM&gt; > To: vanagon &lt;vanagon@GERRY.VANAGON.COM&gt; > Sent: Fri, Aug 12, 2011 3:02 pm > Subject: AC cutting out momentarily > > > > > I was concerned about this after hearing from others about fires etc. in > that area. šMine still had the fuse (fusible link?) but it got too hot > to touch when in use. šThe connections were slightly corroded and one > was loose. šI carefully cleaned the contacts and wahsers with 600 grit > sandpaper and reassembled tightly. šAs a n extra precaution I drilled a > tidy pattern of vent holes in the cover panel below and above this area. > šStill is pretty hot, but I think it is much cooler than before. > > Gregory Smith > > Smith Design Studio > Small Building Company > Olympia, WA > 360-239-0429 > gregoryfsmith.com > > > -------- Original Message -------- > Date: Thu, 11 Aug 2011 20:02:06 -0500 > From: jaime forero &lt;jforero@SBCGLOBAL.NET&gt; > Subject: Re: AC cutting out momentarily > > Hi in my case I have found that on very hot days and after 20-25 minutes > = > of > operating on high speed, 4 on the knob, the wire in the D pillar before > = > the > fuse that feeds juice to the fan gets hot and trips the fuse. A while = > back > the original fuse got so hot that it basically melted the plastic holder > = > so > I replaced it with a resettable fuse. The interesting thing is that the > wires after the fuse going to the fan do not get very hot. I think my > problem has to do with fans getting older and drawing more amps than = > normal > in high speed. Any suggestions?? Should I replace the wire that gets = > hot > with next gauge wire?? All other speeds, 3,2,1 work just fine.=20 > > _________________ > Jaime Forero > jforero@sbcglobal.net > Siempre Adelante!!! > > > > > > > > >


Back to: Top of message | Previous page | Main VANAGON page

Please note - During the past 17 years of operation, several gigabytes of Vanagon mail messages have been archived. Searching the entire collection will take up to five minutes to complete. Please be patient!


Return to the archives @ gerry.vanagon.com


The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.

Any profits from list compilations go exclusively towards the management and operation of the Vanagon mailing list and vanagon mailing list web site.