Date:         Sat, 5 May 2012 10:29:13 -0400
Reply-To:     Dennis Haynes <d23haynes57@HOTMAIL.COM>
Sender:       Vanagon Mailing List <vanagon@gerry.vanagon.com>
From:         Dennis Haynes <d23haynes57@HOTMAIL.COM>
Subject:      Re: Propane Pipelines
Comments: To: Robert Stevens <mtbiker62@GMAIL.COM>
In-Reply-To:  <1A1B11CA-1D70-48F3-8FC8-4573261DBCF2@gmail.com>
Content-Type: text/plain; charset="US-ASCII"

I've been exposed to RV's since my parents got their first one in 1978. They owned three and I am already on my third one. I have also worked on a number of them over the years. In general the propane is plumbed the same as the methods are governed under NFPA and RVIA and the materials need to be UL listed for the application.

From the tank, if single and mounted the regulator is usually on the tank and a hose will connect to a 1/2" or 3/4" black pipe manifold for distribution. Connections to each appliance is dome with copper tube, always using flare fittings, never compression except for some specialties and they will be listed for propane or gas use. My current RV has a slide out room with the stove and refrigerator moving with the room. The flexible hose is in the "basement" and has a bonding wire attached at both ends.

For RV's with dual removable tanks there are usually hoses from each tank to a "changeover" valve or valve regulator combination. The change over valve system includes checks so the gas cannot flow from one thank to the other. Many have the provision the switch over automatically and have an indicator to let you know tank is in use. This also allows for the empty to be disconnected for refill without interrupting service.

Dennis

-----Original Message----- From: Vanagon Mailing List [mailto:vanagon@gerry.vanagon.com] On Behalf Of Robert Stevens Sent: Friday, May 04, 2012 6:28 PM To: vanagon@GERRY.VANAGON.COM Subject: Re: Propane Pipelines

On May 4, 2012, at 3:51 PM, Bill Witz wrote:

> A QUESTION- When I installed my new propane tank i had to cut the > copper lines in order to mate with new tank. I was in a hurry and I > used hose for the output to stove and refer. No leaks but I am wondering about static danger. > So far my westy has not gone up in smoke. Please advise.

Bill, a lot of RV's use gas "hose" rather than copper tubing for propane. I have some hose I'm going to be using to connect my 2 tanks, with brass fittings, etc. The hoses were put together by a very good shop where I live so I'm sure there is not risk there. Since it is an "outside" run of hose, perhaps the rish of rupture is higher from road debris damage. Be sure that any place the hose runs through a metal sheet/wall, that you have a good rubber grommet fitting.

bob


Back to: Top of message | Previous page | Main VANAGON page

Please note - During the past 17 years of operation, several gigabytes of Vanagon mail messages have been archived. Searching the entire collection will take up to five minutes to complete. Please be patient!


Return to the archives @ gerry.vanagon.com


The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.

Any profits from list compilations go exclusively towards the management and operation of the Vanagon mailing list and vanagon mailing list web site.