Date:         Tue, 7 Aug 2012 08:22:57 -0600
Reply-To:     Leonard Sitongia <sitongia@ONEBEAM.NET>
Sender:       Vanagon Mailing List <vanagon@gerry.vanagon.com>
From:         Leonard Sitongia <sitongia@ONEBEAM.NET>
Subject:      Re: Refrigerator gasket and flame goes out remedies
Comments: To: David Vickery <david_vickery@yahoo.com>
In-Reply-To:  <1344348274.32837.YahooMailNeo@web121501.mail.ne1.yahoo.com>
Content-Type: text/plain; charset=iso-8859-15; format=flowed; delsp=yes

On Tue, 07 Aug 2012 08:04:34 -0600, David Vickery <david_vickery@yahoo.com> wrote:

> Your thermocouple sounds fine. The clicking after the flame goes out is > the valve closing off the gas, which happens after the flame has goine > out.. it only takes 1 millivolt to keep that valve open. The > thermocouple will put out 30 millivolts if it is very strong. Mine goes > down as low as 8 when the fridge is running and it works fine, just a > weak thermocouple and that doesn't affect cooling. The lower voltage > affects the LED not being as bright.

That sounds good. Thanks for your ideas.

I think what is curious is that a couple of times it lighted normally, with the flame visible in the window and the LED coming on and the flame is quiet from the flue. Both times, the mode changed to not visible in the window, LED off, rumble from flue. And, other times when it would light, it would be in that second mode. I think the flame is burning in the wrong place, perhaps the gas pressure is too high? I made a manometer, and set the regulator pressure to 11". But, I keep thinking about my elevation (6000'). The air pressure is lower on the water column, so setting to 11" will be lower pressure in the regulator. Or, is it independent of elevation? Anyway, I tried different regulator settings last time I was messing with that, to no avail. I think I will try it again. I also messed with dial C, the temperature setting, to no avail. Anyway, this condition of two modes of the flame and the rumble seems significant to me.

-- ==Leonard


Back to: Top of message | Previous page | Main VANAGON page

Please note - During the past 17 years of operation, several gigabytes of Vanagon mail messages have been archived. Searching the entire collection will take up to five minutes to complete. Please be patient!


Return to the archives @ gerry.vanagon.com


The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.