On 10/3/2012 11:32 AM, Stuart MacMillan wrote: > Problems like this are maddening! Bad auto stop valve or bleed valve that > doesn't vent are the only things that can prevent filling. It's more likely that the tank simply needs to be purged of air, as already mentioned. When the tank has nothing but propane in it, it can be easily filled. Pumping liquid propane in increases the pressure, and the existing propane gas in the tank turns to liquid, making room. For a tank at 80F, that pressure is about 130 psi. If you try to fill a tank which has air in it, the air simply compresses, and pressure goes up. New tanks are often shipped with compressed air in them, so you can't push much propane in before the pressure gets too great to be able to pump more. Hence, the need to purge the air from the tank before first use. |
Please note - During the past 17 years of operation, several gigabytes of
Vanagon mail messages have been archived. Searching the entire collection
will take up to five minutes to complete. Please be patient!
Return to the archives @ gerry.vanagon.com
The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.