Sounds like a good reason to install a properly sized fuse inline with a wire gauge upgrade. Perhaps an alternator upgrade would also be in order? Any voltage drop across your headlight/radiator fan/blower motor supply wire implies waste heat being dumped from the wire. Power = current x voltage. A 2 volt drop in a supply wire with a 20 amp load is 40 Watts wasted. On 11/17/2013 6:35 PM, Dennis Haynes wrote: > Most auto equipment will work over a large voltage range but performance > does suffer. However it is not by accident or even cost savings that the > wiring is "undersized". As the system gets loaded down thee resistances help > to control the load on the alternator. Also, as so much wiring is not over > current protected the smaller sizes also help to limit or control fault > currents. Yes those wires can act as fuses hopefully burning up enough to > open before the van is gone. |
Please note - During the past 17 years of operation, several gigabytes of
Vanagon mail messages have been archived. Searching the entire collection
will take up to five minutes to complete. Please be patient!
Return to the archives @ gerry.vanagon.com
The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.