Wouldn't the X terminal get power in the START position and lose power in the RUN position to properly activate the load reduction relay? Mike B. On 10/18/2014 3:26 AM, David Beierl wrote: > At 08:34 PM 10/17/2014, Geneva Saint-Amour wrote: >> Is there a diagram out there which labels each of the spades on the >> ignition switch? One of ours has nothing on it and we are curious >> as to what it is for. > > 30 - Supply voltage from battery. > 50 - output to starter solenoid, on in start position. > X - output to load reduction relay and headlights, on in run position. > P - not used (and not present in some aftermarket switches), on in > off position. > 15 - switched output to vehicle components, on in run and start > positions. > SU - switched output to key alarm, on when key is inserted (this is a > very low-current switch). > > Yours, > David |
Please note - During the past 17 years of operation, several gigabytes of
Vanagon mail messages have been archived. Searching the entire collection
will take up to five minutes to complete. Please be patient!
Return to the archives @ gerry.vanagon.com
The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.