John, The different panels will have a somewhat different I to V curve, and thus the maximum power point for each may be a bit different. Depending on the MPPT controller, this may mean a reduction in power transfer efficiency, but should still charge the battery. Some MPPT controllers generate a particular I to V curve for the attached panels, by sampling over time and various light conditions. Still better than a straight PWM approach. Jon
On 5/28/2015 8:08 PM, J B wrote: > The initial test run seemed to work great and pulled in over 10amps during peak sunshine |
Please note - During the past 17 years of operation, several gigabytes of
Vanagon mail messages have been archived. Searching the entire collection
will take up to five minutes to complete. Please be patient!
Return to the archives @ gerry.vanagon.com
The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.