needless to say, what temp it starts to open at would depend on the temp rating of the t-stat. if Don has a 'par' value stat ..say 180F .. I would expect start of opening to be a bit above 170 F or so. and why not use water ? that's what the books show I believe. Scott On 9/15/2015 9:23 AM, David Beierl wrote: > At 02:58 PM 9/12/2015, Don Hanson wrote: >> Is there an accepted method to test the function of one of our double >> style thermostats? I am skeptical about the proper operation of my >> currently installed one.... lately....I have had some other issues with > > Put it in a pan of vegetable oil or 100% gycol antifreeze (caution: > both are flammable) and heat it on a stove. Opening begins > ~85C/185F. Opening complete ~105C/221F. Minimum opening stroke 8 > mm/.35 in. > > Yrs, > d > |
Please note - During the past 17 years of operation, several gigabytes of
Vanagon mail messages have been archived. Searching the entire collection
will take up to five minutes to complete. Please be patient!
Return to the archives @ gerry.vanagon.com
The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.