Date:         Tue, 15 Sep 2015 09:37:29 -0700
Reply-To:     Pat Spragge/RFAN <Pat.Spragge@RFAN.COM>
Sender:       Vanagon Mailing List <vanagon@gerry.vanagon.com>
From:         Pat Spragge/RFAN <Pat.Spragge@RFAN.COM>
Subject:      Re: Starter hesitation
Comments: To: Stuart MacMillan <stuartmacm@GMAIL.COM>
In-Reply-To:  <095801d0efd4$578fc710$06af5530$@gmail.com>
Content-Type: text/plain; charset="US-ASCII"

Check the grounds...do a voltage drop check on the starter as it may not be seeing the full 12+V...or could be the case that Stuart stated

Patrick

From: Stuart MacMillan <stuartmacm@GMAIL.COM> To: vanagon@GERRY.VANAGON.COM Date: 09/15/2015 09:34 AM Subject: Re: Starter hesitation Sent by: Vanagon Mailing List <vanagon@gerry.vanagon.com>

You can try a relay (get a sealed one, like T3's to prevent accidental shorting), but that didn't work for me. These starters are weak to begin with, and the rebuilt units are junk too (garbage in, garbage out). This is the real fix: http://www.gowesty.com/ec_view_details.php?id=23528&category_id=&category_parent_id=

The current through the ignition switch isn't all that huge--a pulse of current to throw the solenoid, and a much smaller amount to keep it engaged while cranking. The solenoid itself makes the high current connection from the battery directly to the starter. Often the solenoid is the problem, or it's a combination of both parts being "weak".

Stuart

-----Original Message----- From: Vanagon Mailing List [mailto:vanagon@gerry.vanagon.com] On Behalf Of Rick Cooper Sent: Tuesday, September 15, 2015 9:10 AM To: vanagon@GERRY.VANAGON.COM Subject: Starter hesitation

Since buying it earlier this year, the starter on my 87 Westy hesitates when I turn turn the ignition to start. There's an initial 'umph' -- starter gives kind of a push, then it stops for 1/4 to 1/2 a second before it starts again and, this time, carries on to start the engine. Have I got a bad connection and, if so, where might it be? I've heard of installing a relay somewhere in the starter circuit -- would that help? What kind of relay do I need and where in the circuit would it go?

Thanks for any pointers,

Rick


Back to: Top of message | Previous page | Main VANAGON page

Please note - During the past 17 years of operation, several gigabytes of Vanagon mail messages have been archived. Searching the entire collection will take up to five minutes to complete. Please be patient!


Return to the archives @ gerry.vanagon.com


The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.