Glad to hear it!

On Fri, Jun 16, 2017, 7:48 PM rick Duvernay <richard.duvernay@sbcglobal.net> wrote:

> Relay worked like a charm. I now have all three speeds with the A/C > blower. Thanks Ken! > > Sent from my iPhone > > > On Jun 12, 2017, at 2:17 PM, kenneth wilford <kenwilfy@GMAIL.COM> wrote: > > > > Sounds good. > > Ken Wilford at vanagain.com > > > > On Jun 12, 2017 5:06 PM, "rick Duvernay" <richard.duvernay@sbcglobal.net > > > > wrote: > > > >> Okay. I ordered the relay and will post result. Thanks! > >> > >> Sent from my iPhone > >> > >>> On Jun 12, 2017, at 2:48 PM, kenneth wilford <kenwilfy@GMAIL.COM> > wrote: > >>> > >>> There is no other relay like this one on the van. It tries to do about > >>> three or four different things and is usually the root of fan weirdness > >> on > >>> the 86-91 Vanagon AC system. Here is a link to it in our store if you > >> want > >>> to buy a new one. > >>> > >>> https://www.vanagain.com/shop/ac-fan-relay/ > >>> > >>> Ken > >>> > >>> On Mon, Jun 12, 2017 at 2:32 PM, rick Duvernay < > >>> richard.duvernay@sbcglobal.net> wrote: > >>> > >>>> Thanks Ken! Is there another similar relay in the van I can swap out > to > >>>> test and would a replacement be available through you or another > vendor? > >>>> > >>>> Sent from my iPhone > >>>> > >>>> On Jun 12, 2017, at 1:25 PM, kenneth wilford <kenwilfy@gmail.com> > >> wrote: > >>>> > >>>> Actually many times this is caused by a relay in the rear air > >> conditioning > >>>> system. It is the tallest of the three relays that are over in the > left > >>>> rear pillar that has the number 13 on the top. > >>>> > >>>> Ken Wilford at vanagain.com > >>>> > >>>> On Jun 12, 2017 2:19 PM, "rick Duvernay" <richard.duvernay@sbcglobal. > >> net> > >>>> wrote: > >>>> > >>>>> Folks- > >>>>> > >>>>> I have an 87 gl camper. The rear ac blower motor only operates on > high > >>>>> speed. I changed out the front switch on the dash. It made no > >> difference. > >>>>> Is there a resistor in back near the blower motor that I should > change? > >>>>> Six months ago I removed the dash and changed out the front blower > >> motor > >>>>> and resistor (after cleaning out the mouse nest). I saved the old > >> resister > >>>>> from the front. Can I use that? I have a Bentley, but I never > >> learned how > >>>>> to read wiring diagrams. Any suggestions would be appreciated. > >>>>> > >>>>> Rick > >>>>> > >>>>> Sent from my iPhone > >>>> > >>>> > >> > >> > >


Back to: Top of message | Previous page | Main VANAGON page

Please note - During the past 17 years of operation, several gigabytes of Vanagon mail messages have been archived. Searching the entire collection will take up to five minutes to complete. Please be patient!


Return to the archives @ gerry.vanagon.com


The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.

Any profits from list compilations go exclusively towards the management and operation of the Vanagon mailing list and vanagon mailing list web site.