If grounding the sender lead doesn't give a green LED, the common reason is that the LM324N 12-pin DIP chip on that side has gone bad. DigiKey has them for USD 0.50 in singles. Any electronic parts place should have them. For easy removal, clip the chip from its leads and remove them individually. https://www.digikey.com/product-detail/en/texas-instruments/LM324N/296-1391-5-ND/277627 Yrs, d On Fri, Jul 28, 2017 at 12:47 PM, gilles.turmel <gilles.turmel@sympatico.ca> wrote: > À friend of mine has an 86 Westfalia, no light is showing from the water > tank level sensor. The sensor was changed, no lights. Anyone has a clue on > the problem. Best regards. > > > Envoyé de mon appareil Samsung de Bell via le réseau le plus vaste au pays. |
Please note - During the past 17 years of operation, several gigabytes of
Vanagon mail messages have been archived. Searching the entire collection
will take up to five minutes to complete. Please be patient!
Return to the archives @ gerry.vanagon.com
The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.