I mostly agree with Karl here. If the starter cranks as well (or poorly)
from the key as it does by jumpering the 50 terminal at the starter, then
there is nothing to be gained in terms of the starter working. If it
doesn't, then it's arguably as easy to fix the poor connection as to
install a starter relay. I say connection because wires don't get tired,
but crimps and connections do when left out in the weather the way VAG did.
That said, the relay does reduce the stress on ignition switch contacts.
The solenoid is an inductive load, so it arcs more at the switch contacts
than a similar resistive load. The switches I've taken apart (no Kostal
ones yet) show pitting and arc burns on the the center contact at the 30
terminal, which seems to do most of the actual make-and-break switching. I
tried to look at one just now to verify my recollection, but too many
pieces were missing for me to make sense of it. It's kind of a horror
inside -- the key-inserted switch complicates things considerably.
Yrs,
d
On Fri, Jun 15, 2018 at 1:48 PM, Karl <tdiguru@westyventures.com> wrote:
> I've never in 35 years of working on these seen a need for an additional
> relay, so we'll have to agree to disagree here. If all connections are
> clean and strong there is no need for bandaids. The required current to
> activate the starter is quite small. Wires don't 'get tired'.
>
>
>
>
> On 6/15/2018 9:13 AM, OlRivrRat wrote:
>
>> On 15 Jun , 2018, at 1:11 AM, Karl Mullendore wrote:
>>
>> Easy fix - get rid of the unnecessary relay - as was done. The TDI starter
>>> doesn't need this added complexity.
>>>
>>
>> I Strongly Disagree with this ~ Anything that can be done to
>> Lighten the Load
>>
>> on Our Van's Old & Tired Wires & Switches & Connectors is a Good Thing ~
>> Especially
>>
>> in Instrument Cluster & FuseBlock area ~
>>
>> The TDI Starters Efficiency is a Big Help but without a Start Relay
>> the Current
>>
>> required to Hold the Starter Solenoid is Still having to pass through the
>> Entire Length
>>
>> of the 50Circuit, All its Connect's & the Igni'Switch < That is what is
>> Unnecessary ~
>>
>> ORR ~ DeanB
>>
>>
|