Date:         Mon, 13 Aug 2018 13:38:19 -0400
Reply-To:     David Beierl <dbeierl@ATTGLOBAL.NET>
Sender:       Vanagon Mailing List <vanagon@gerry.vanagon.com>
From:         David Beierl <dbeierl@ATTGLOBAL.NET>
Subject:      Re: temp gauge not working right...
Comments: To: Dan N <dn92610@gmail.com>
In-Reply-To:  <CAFdLW6ked2Y8wM5RPGasgciVQquWE9ztaAOV1Qy8ASMRpkmYDw@mail.gmail.com>
Content-Type: text/plain; charset="UTF-8"

> > David, I would think there's no ground between the thermostat housing and > the engine... if it's so then I will add a flat braided copper ground to > the housing...

Voltmeter will tell you *exactly* where the issue is. Locate the point where ten volts changes to zero volts and you have found the problem.

> thanks again

You're welcome.

Yrs, d


Back to: Top of message | Previous page | Main VANAGON page

Please note - During the past 17 years of operation, several gigabytes of Vanagon mail messages have been archived. Searching the entire collection will take up to five minutes to complete. Please be patient!


Return to the archives @ gerry.vanagon.com


The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.