Date:         Wed, 30 Sep 2020 12:24:35 -0700
Reply-To:     Dan N <dn92610@GMAIL.COM>
Sender:       Vanagon Mailing List <vanagon@gerry.vanagon.com>
From:         Dan N <dn92610@GMAIL.COM>
Subject:      Re: Melted ground wire
Comments: To: Neil N <musomuso@gmail.com>
In-Reply-To:  <CAB2RwfhWhQGw4a8Di6EpqbD-CiE=m5ka8XDKNiHvUgyEv=dupg@mail.gmail.com>
Content-Type: text/plain; charset="UTF-8"

thank you Neil,

*Did a wire come loose from a relay unrelated to the headlight circuits and upgrade parts? * - No, no loose wire on any relay.

*Was this the cause of the short or a result of another short? i.e. did something else go haywire and cause the 53 relay ground to heat up then short out to a neighbouring relay pin?* - No, no other short, nothing that I can see after close inspection, the relay looks fine, no burning or melting traces but I am not sure about the internal.

*Bentley 88/89 Vanagon wiring diagrams show the stock headlight fuses at 10 Amp each. There were 20 Amp fuses in those positions now replaced with 15 Amp fuses?* - Thanks a lot here, Yes I replaced them with 20A but I will put 10A on fuses 20,21,9,10 as per Bentley but Jay Browns recommends 20A, I will pass this and go back to 10A.

*I'd be curious if the relay ground wire touched the 87/30 wires or positive wire to relay coil (likely 86).* - Yes, it's the case here. The ground wire gets hot, melts the plastic sleeve, touches the 86 (+) wire and short everything. The 53 relays are coming soon from GoWesty.

thanks again,

dan

On Wed, Sep 30, 2020 at 11:42 AM Neil N <musomuso@gmail.com> wrote:

> Wires are labelled with different temp ratings. I'm not certain if > those ratings apply *only* to ambient temps around the wire and how > they might affect the wire casing but i do know that the real issue > with a dead short on an UN-fused wire isn't about wire gauge, per se, > it's about the temp, and rate, at which the casing melts off. e.g. in > a situation where that UN-fused wire suffers a dead short, if the > casing melts off quickly, the exposed wire strands can get red hot an > it can take some time before they actually melt and break the circuit. > > I'm not overly familiar with the later (1988 ?) Vanagon fuse/relay > arrangement. > > Did a wire come loose from a relay unrelated to the headlight circuits > and upgrade parts? Was this the cause of the short or a result of > another short? i.e. did something else go haywire and cause the 53 > relay ground to heat up then short out to a neighbouring relay pin? > > I assume you meant "1988 Carat". Bentley 88/89 Vanagon wiring diagrams > show the stock headlight fuses at 10 Amp each. There were 20 Amp fuses > in those positions now replaced with 15 Amp fuses? > > I'd be curious if the relay ground wire touched the 87/30 wires or > positive wire to relay coil (likely 86). But, that type of relay is > cheap and depending on its' purpose, it could be replaced with a > generic FLAPS sourced 4 or even 5 pin "bosch" type relay. > > Neil. > > > > On 9/30/20, Dan N <dn92610@gmail.com> wrote: > > > > My daughter drove her 1998 Carat (stock) with high beams ON and suddenly > > smoke came out under the dash, engine died, she pulled over, shut the > > engine, waited a bit and restarted the van and the same thing happened > > again, got it towed to me. > > The van has Jay Brown's headlight relay kit but uses 55/80W bulbs 6 years > > ago and working fine till now. The fuses 20,21(low beam) are OK, the > casing > > of the fuses 9,10(high beam) were melted but the fuses are not blown. In > > the back of the fuses panel there is a gray #53 relay and the ground (-) > > wire that goes to the ground tree was melted and touched the positive (+) > > wire on the same relay. > > I replaced the 4 fuses (20,21,9,10) with 15A fuses instead of 20A, > repaired > > the positive (+) wire, replaced the ground (-) wire with 14 gauge instead > > of 16 gauge and installed an inline 10A fuse on it. I ordered a new #53 > > relay (not here yet) just in case. All working well now. > > > > Sorry for the long description but I try to find out why this could > > happen... quite scary and I wonder how to prevent this. > > > > Thank you for any ideas. > > > > dan > > > > > -- > Neil n > > VE7TBN > > 1988 Westy 50º ABA swap: https://tinyurl.com/yap5hpwt > > 1981 Westy 15º ABA swap: https://tinyurl.com/y9n4xob8 > > VAG Gas Engine Swap Group <http://tinyurl.com/khalbay> >


Back to: Top of message | Previous page | Main VANAGON page

Please note - During the past 17 years of operation, several gigabytes of Vanagon mail messages have been archived. Searching the entire collection will take up to five minutes to complete. Please be patient!


Return to the archives @ gerry.vanagon.com


The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.

Any profits from list compilations go exclusively towards the management and operation of the Vanagon mailing list and vanagon mailing list web site.