--SweetPea70@aol.com said:-- > My red GEN light came on and now stays on all the time. She runs > normally, but the light beckons......is it true I will have to remove the > entire engine if the gen. is kapoot??(('71 Camper) My volt. reg. is behind my > air cleaner for some reason....Any suggestions would be helpful : D It's probably easier to drop the engine to change the generator, but I've done it with the engine in....and if you don't have the setup to drop the engine, it's an option. I think it's in Muir, but basically what you do is undo the bolts under the manifolds holding the shroud and block up the shroud a coulple of inches to get the fan over the generator stand. Helps to have small hands..... Do the Muir thing with the wires and brushes and popsicle stick first though.... -- Todd R. Schroeder | Without vision, a people perish. todds@sunnet.chotel.com | Proverbs xxix:18 '71 Campmobile
|
Please note - During the past 17 years of operation, several gigabytes of
Vanagon mail messages have been archived. Searching the entire collection
will take up to five minutes to complete. Please be patient!
Return to the archives @ gerry.vanagon.com
The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.
Any profits from list compilations go exclusively towards the management and operation of the Vanagon mailing list and vanagon mailing list web site.