> From: daukes@mmts.eds.com (dean c aukes) : > or 110 VAC (330 Hz) @ 150 W So why is everybody so afraid of this 330Hz? I agree, don't test it on your laptop (to expensive experiment), (and stay away from that 650V DC), but I don't see why feeding a standard E or ring core transformer 330Hz instead of 50 or 60 would be such a big deal. Sure, lossess due to hysteresis would be slightly higher, but the risk of saturating the core would be less. I have used standard power supply E-core transformers up to several kHz without any problem. Things that might not work so well is anything that tries to do something with the AC directly, eg the timing in simple "dimmer" type circuits may not work very well. Also, AC motors may burn out easily. Typical electric drill motors would work fine though. /Martin (Flamesuit on)
|
Please note - During the past 17 years of operation, several gigabytes of
Vanagon mail messages have been archived. Searching the entire collection
will take up to five minutes to complete. Please be patient!
Return to the archives @ gerry.vanagon.com
The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.