Date:         Mon, 4 Dec 1995 10:27:26 -0500
Sender:       Vanagon Mailing List <vanagon@vanagon.com>
From:         "Morris H. Arthur" <marthur@gibbs.oit.unc.edu>
Subject:      Re: Recirculating heat in '74-'79 camper (update)

My weekend was spent wrestling tubing underneath the bus...

Summary: The heat direction box under the floor can't be used as I described it in my earlier post because when the small tubes are opened via the control cable, they do not block flow from the large tubes. In the situation I described, there would still be fresh air entering the heat intake along with the interior air. Since the heat system is still going to get fresh air from your main cooling fan, I don't think the option of choosing fresh air for the auxilary input is all that important. I'm going to try ducting the vent from underneath the back seat, around in front of the valve covers for 3 and 4, and through the engine tin to the aux fan.

John from WV had an interesting suggestion about reversing flow through one of the heat exchangers. I'm sort of scared to create a heating imbalance on different sides of the engine...

Contact me if you want to know main tube replacement recommendations...

--------------------------------------------------------- Morris Arthur < morris_arthur@unc.edu > Environmental Sciences and Engineering University of North Carolina


Back to: Top of message | Previous page | Main VANAGON page

Please note - During the past 17 years of operation, several gigabytes of Vanagon mail messages have been archived. Searching the entire collection will take up to five minutes to complete. Please be patient!


Return to the archives @ gerry.vanagon.com


The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.