Subject:      Re: 82 fi electrical question

John, You've obviously switched the two leads. The aux air reg gets 12V from the time the engine is switched on to the time it's switched off. The cold start valve only gets voltage when the starter is engaged.

To check this, just pull the connector to the cold start valve and start the engine. If it purrs like a kitten then the problem's solved.

Btw, running the engine with the connector off won't hurt the brain. It's a straight 12V connect off a relay.

Jack


Back to: Top of message | Previous page | Main VANAGON page

Please note - During the past 17 years of operation, several gigabytes of Vanagon mail messages have been archived. Searching the entire collection will take up to five minutes to complete. Please be patient!


Return to the archives @ gerry.vanagon.com


The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.

Any profits from list compilations go exclusively towards the management and operation of the Vanagon mailing list and vanagon mailing list web site.