Lionel; First ; the two wires leading to the expansion tank only check for absence of coolant not temperature. The sender that affects your temp gauge has ONE wire and is located on the thermostat housing. It is next to the sensor with TWO wires which sends information to the computer, they work independent of each other. Disconnecting the single wire will only make the gauge read "cold". If you disconnect it and short it to ground you will "peg" the needle in the hot zone and cause the LED to flash. It may take a few seconds to react. To test your fan: Turn on van, and start your air conditioner. The fan should immediately come on low. Check the fuses if not. The fan should keep the needle pretty close to middle if your system is working properly. I would start with a new thermostat and go from there. Good Luck Ken Lewis kdlewis@juno.com 86 VW crewcab 85 VW Vanagon GL 60 356 coupe
|
Please note - During the past 17 years of operation, several gigabytes of
Vanagon mail messages have been archived. Searching the entire collection
will take up to five minutes to complete. Please be patient!
Return to the archives @ gerry.vanagon.com
The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.