Well, in the quest to find what is causing my 84 to flood and run rich, I've run into a question that the Bentley is a bit vague about. I've pulled the airflow sensor to test it. The temp sensor reads right. Unfortunately terminals 3 and 4 give 100 ohms resistance (Bentley says 500-1000) so I am assuming that something is bad. The problem is that the Bentley only says that resistance between terminals 2 and 3 should "vary" as you move the airflow flap. Well it varies, not smoothly, but in a seemingly random way from 0ohms (flap closed) up to 4000ohms if I push it in really smoothly, and back down to about 100ohms. What should it do? Thanks, ___________________________________________________________________________
Bob O'Shaughnessy 84GL, 85GL project
|
Please note - During the past 17 years of operation, several gigabytes of
Vanagon mail messages have been archived. Searching the entire collection
will take up to five minutes to complete. Please be patient!
Return to the archives @ gerry.vanagon.com
The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.