Date:         Mon, 07 Jul 1997 08:16 -0600 (MDT)
Sender:       Vanagon Mailing List <vanagon@vanagon.com>
From:         BLAINE_BACHMAN%PL-01M3@ccmail.plk.af.mil
Subject:      Dometic fire alert (at least for the 182B)

First let me admit that my experience may have been a fluke.

You may recall that a week ago I described a situation which rendered my fridge partially inoperative. I was pre-cooling it on propane, parked the car in front of the house, came out 10 minutes later and opened the sliding door, and was greeted by a rush of smokey air (like someone had smoked a cigarette or two inside with the windows shut).

Anyway, the 8A fuse (behind the driver's seat) was blown and the circuit was shorted. In reviewing the wiring diagram, I surmised that the fan motor had shorted out. In order to run the fridge on 12V and 110V, I pulled the one wire from the three-prong plug (though of course I would be running without the fan, and wouldn't have the propane ignitor).

Well, I pulled the fridge this weekend and here's what I found:

The fan had caught fire! The motor was there, but the fan blade assembly (and all other plastic pieces of the motor) was gone.

The wires were melted off and fused together.

BUT IT GETS WORSE

There's a 2" high portion of the wall paneling that "frames" the backside of the opening; a 3" wide section of this was burned down to the floor (probably as a result of the burning, melted plastic of the fan blades dripping down on it).

Why the whole vehicle did not go up in smoke, I don't know!

THE FIX (I think)

I was never too happy with the fan motor circuit having power all the time, even when the fridge was not operating (it gets hot enough here in New Mexico to kick the fan on when the car is sitting in the parking lot), and since there didn't seem to be an "automatic" way, I decided to install a switch. And while I'm at it, a secondary fuse (with a lower rating, to be sure).

I had already purchased one muffin fan (cigarette pack size in Derek Drew's "fridge manual") to add to the back. I returned to Radio Shack and bought another one, part # 273-243 (to make it two), plus the small one 273-240 to install inside, a low profile DPDT rocker switch 275-695 (mounts in a 5/8" hole), a low profile panel mount fuse holder 270-368, some 5A slo-blow fuses (though I think I'm gonna go back and get some even lower-rated ones - say 3-amp), and nylon wire ties. I also picked up (elsewhere) a sheet of aluminum, 14 gauge automotive wire, some clear silicon, and shrink tubing.

Examining the "control" panel atop the fridge, I found that there was space for the rocker switch right were the Dometic logo was, and that the fuse holder could be installed between the pump and the thermocouple hold-down button. I drilled the two appropriately-sized holes using wood-boring "spade" bits at low speed in an electric drill (this is THE way to drill plastic; twist drills don't cut perfectly round holes).

After determining the proper orientation for the fans, I tie wrapped them together through their mounting holes, and then tie wrapped them to the bottom of the lower set of "fins" - BTW, how hot do the fins get? Are the fins likely to fatigue the wire ties to the point of breakage? Should I figure out another system to mount them?

I connected the wire pairs from the fans - oddly, the RED wire is the negative and the BLUE wire is the positive - and after slipping shrink tubing on the wires, soldered the RED fan wires to the fridge's BLUE ground wire, and the BLUE fan wires to the fridge's YELLOW wire which comes from the thermo switch. Slid the shrink tubing over the solder joints and shrank it.

I opened up the cover over the terminal block and found the yellow wire that goes to the thermo switch and removed it. I then installed a new wire from the terminal block to the "in" side of the fuse, a wire from the "out" side of the fuse to the two center terminals on the rocker switch, and a wire from one of the "on" terminals of the rocker switch back to the yellow wire that leads to the thermo switch (again insulated with shrink wrap). I made sure to run the wires along with others, wire-tying them as needed and keeping them away from moving parts. I now have a fused and switched circuit to control the fans. I also installed the small fan inside the fridge with silicon, drilled a small hole in the top for the wires to pass through, grounded the RED wire at one of the grounding terminals, and extended the BLUE wire to run to the second available "on" terminal on the rocker switch. Now the switch will also control the inside fan.

I squeezed silicon all around the hole where the wires go to the inside fan to seal the hole and protect the wires. I also reinstalled the terminal cover.

Before I reinstall the fridge, I'm gonna line the rear "floor" and lower back wall of the opening with some of the aluminum sheet.

Hopefully all of this work will make the fridge safer to use (and leave unattended for 10 minutes!) in the future. I think I'm gonna install a smoke detector, too!

Please, please pass on any comments you may have about my ideas.

-Blaine


Back to: Top of message | Previous page | Main VANAGON page

Please note - During the past 17 years of operation, several gigabytes of Vanagon mail messages have been archived. Searching the entire collection will take up to five minutes to complete. Please be patient!


Return to the archives @ gerry.vanagon.com


The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.

Any profits from list compilations go exclusively towards the management and operation of the Vanagon mailing list and vanagon mailing list web site.