Scott- I'm no plumber, but I can assure you that it is not necessary, and perhaps even unwise to put plumber's (teflon) tape on the compression fittings of the propane line. The sealing surface is not the threads, but rather the thin "bead" where the copper pipe itself mates up to the male fitting coming out of the fridge. If this seal is not being made, the teflon tape will only mask the problem, and maybe not permanently. Another problem is that the tape itself, especially if applied by the unknowing (let's see...if one turn of tape is good, then three or four must be great, right?). In this case, the tape may actually prevent the line from seating and thereby sealing properly. Finally, with teflon being so slippery, it may actually be possible to overtighten and even fracture the fittings. I say, best to not try and improve on the factory procedure in this case. -Blaine
|
Please note - During the past 17 years of operation, several gigabytes of
Vanagon mail messages have been archived. Searching the entire collection
will take up to five minutes to complete. Please be patient!
Return to the archives @ gerry.vanagon.com
The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.